How to hang the wind speed sensor in the coal mine roadway

A wind speed sensor shall be installed at the wind measurement station of the return wind tunnel, the one wing return airline and the total return air lane. The wind speed sensor shall be set at a location within 10m before and after the roadway without branching wind flow, no turning, no obstacles, no change in section, and accurate calculation of air volume. When the wind speed is less than or exceeds the value specified in the “Safety Regulations for Coal Mines”, an audible and visual alarm signal shall be issued.

What is the supply voltage of wind speed and direction sensor ec9-1?

Generally 24V
The sensor is a detecting device that can sense the measured information and can transform the sensed information into an electrical signal or other required form of information output to satisfy the information transmission, processing, storage and display. Requirements for recording, control and control.
The characteristics of the sensor include: miniaturization, digitization, intelligence, multi-function, systematization, and networking. It is the first stage in achieving automatic detection and automatic control. The existence and development of the sensor allow the object to have senses such as touch, taste and the smell, and let the object slowly become alive. Generally, it is split into ten categories, such as thermal element, photosensitive element, gas sensor, force sensor, magnetosensitive sensor, humidity sensor, sound sensor, radiation sensor, color sensor and taste sensor, according to its basic sensing function. .

What is the difference between the wind speed sensor and the air volume sensor?

Not the same, but the two are related, the air volume is equivalent to the product of the wind speed and the cross section of the through-flow port, so the air volume sensor should be the converted wind speed sensor.

The sensor (English name: transducer/sensor) is a detection device that can sense the measured information and can transform the sensed information into an electrical signal or other required form of information output to respond to the information. Requirements for transmission, processing, storage, display, recording, and control.

The characteristics of the sensor include: miniaturization, digitization, intelligence, multi-function, systematization, and networking. It is the first stage in achieving automatic detection and automatic control. The existence and development of the sensor allow the object to have senses such as touch, taste and the smell, and let the object slowly become alive. Generally, it is split into ten categories, such as thermal element, photosensitive element, gas sensor, force sensor, magnetosensitive sensor, humidity sensor, sound sensor, radiation sensor, color sensor and taste sensor, according to its basic sensing function.

What is the working principle of the marine wind speed and direction sensor?

Wind direction wind speed sensor, as its name implies, is a tool to measure wind direction wind speed. It converts the flow velocity variable of air into a signal with a certain corresponding output signal, which can be applied to the measurement level of meteorological, military, aviation, seaport, environmental protection, industry, agriculture and forestry departments. The need for wind parameters.
In these fields of application, wind direction and wind speed are very important parameters, and the wind direction anemometer has become a universal measuring tool. The wind direction anemometer contains two sensors, a wind direction sensor and a wind speed sensor. These two sensors can work simultaneously, measuring two parameters of wind direction and wind speed.
The induction component of the wind speed sensor of the wind direction wind speed monitor is a three-cup type wind cup assembly. When the wind speed is higher than 0.4 m/s, the rotation is generated, and the signal conversion circuit is a hall integrated circuit. Under the horizontal wind driven, the wind cup group rotates, and the magnetic rod disk rotates through the main shaft. Dozens of small magnets on the magnetic pole from a plurality of rotating magnetic fields, and the pulse signal is induced by the Hall magnetosensitive element, and the frequency thereof increases with the wind speed. Large and linear increase. Calculation formula: V=0.1F; V: wind speed, unit: m/s; F: pulse frequency, unit: Hz.
The wind sensor of the wind direction wind speed monitor has a single-plate wind vane with an auxiliary target at the opposite end. The angle conversion requires a seven-digit Gray code photoelectric code disk. When the wind vane rotates with the wind, the code wheel rotates through the main shaft. Each rotation of 2.8125, seven sets of illumination and receiving optoelectronic devices located on the upper and lower sides of the code wheel will generate a new set of seven-bit parallel gray code, which will be shaped and inverted. Phase output. The azimuth-angle-Gray code-binary code comparison table is a key basis for wind direction measurement microcontroller programming.
In general, the two sensors of the wind direction wind speed monitor get the characteristics of good dynamic performance, high linear precision, high sensitivity, wide measuring range, good interchangeability and superior wind resistance.
Below we briefly introduce some of the highest performance and technical parameters of the downwind wind speed monitor.
The wind direction anemometer consists of three modes: manual, automatic and computer lock. The three modes can be established by users according to their needs. Data storage is powerful and can store up to 60,000 data. The wind direction anemometer has 32 channels of simultaneous detection, enabling multi-point synchronized detection.

What type of sensor is the wind speed sensor, is it a pressure sensor or? What is the working principle?

The wind speed sensor is a wide range of wind speed (air flow rate) transmitters for monitoring, control and wind speed regulation and ventilation systems.

Features:
· Convert air flow rate to 4-20mA or a 0-10V signal
·Linear signal output
· Made of adjustable resistance material
·All electronic instrument reading air flow rate
·AC or DC power supply
·With temperature compensation
·Sleeve sensor for installation
·0-10V temperature output signal
·Fuse protection Application: ESF—35—2 air flow converter has a wide range of applications
·Measure air flow rate via PLC/remote site/EMS
·Adjust air flow rate ·Monitor air flow rate

Wind speed sensor considerations

Two prohibitions:
1. It is forbidden to use a wind speed sensor in flammable gas environment.
2. It is prohibited to place the wind speed sensor probe in flammable gas.
Seven don’t:
1. Do not disassemble or modify the wind speed sensor;
2. Do not expose the probe and the anemometer body to the rain;
3. Do not touch the internal sensor part of the probe;
4. Do not place the anemometer in a place with high temperature, high humidity, dust and direct sunlight;
5. Do not wipe the wind speed sensor with a volatile liquid.
6. Do not drop or press the wind speed sensor;
7. Stay away from the sensor part of the probe while the anemometer is energized.

Three MUST: Be sure to use the wind speed sensor correctly according to the requirements of the instruction manual; in use, if the wind speed sensor emits an abnormal smell, sound or smoke, or if liquid flows into the anemometer, be sure to turn off the battery immediately; the wind speed sensor is long-term. Always remove the internal battery when not in use.
1. The wind direction sensor is removed from the package and assembled. The point of attention is: the wind mark rod is inserted in the direction of the arrow; the front and rear weights of the wind direction indicator should be adjusted, and the front and rear wings should be in the same plane as the rotation axis; the north pole and the north line should be In the same direction.
2. The sensor component is composed of a wind speed sensor, a wind direction sensor and a sensor bracket. When assembling, the sensors should be connected to the respective inserts, then sat on the bracket sleeve, and tighten the screws.
3. The working voltage of the sensor is usually 5 VDC. Owing to the built-in lightning protection device, the actual working voltage should not exceed 6 volts.

Circuit diagram of wind cup type wind speed and direction sensor

The wind cup anemometer has a fixed reed switch inside and a magnet that rotate with the wind cup. The measuring instrument calculates the wind speed according to the number of time the reed switch is engaged per minute.
The wind direction sensor has a 360-degree sliding wire resistor inside, and the rotating arm is attached on the wind swing that rotates with the wind. Different wind directions correspond to different resistance values, and the resistance can be utilized to know the wind direction.

What is the alarm value and the number of points of the mine wind speed sensor?

Mine oxygen sensor alarm value is 19%, the mine carbon dioxide alarm value is 2000ppm. Oxygen sensors are a critical component in engines that use three-way catalytic converters to reduce exhaust pollution. Since the air-fuel ratio of the mixture differs by the theoretical air-fuel ratio, the purification ability of the three-way catalyst for CO, HC and NOx will drop sharply. Therefore, an oxygen sensor is installed in the exhaust pipe to detect the concentration of oxygen in the exhaust gas, and The ECU sends a feedback signal, and then the ECU controls the increase and decrease of the fuel injection amount of the injector to control the air-fuel ratio of the mixture to be near the theoretical value.

The gas sensor T1 is mounted on the roadway which is no more than 5 m from the heading. The methane sensor T2 is installed within the range of 10-15m of the return air inlet. The methane sensor must be suspended vertically above the roadway, no more than 300mm from the top plate, and not less than 200mm from the roadway. T1 alarm concentration is 0.8%CH4, power-off concentration≥0.8%CH4, re-concentration concentration<0.8%CH4, T2 alarm concentration≥0.8%CH4, power-off concentration≥0.8%CH4, re-concentration concentration<0.8%CH4