Wind direction and are often used with anemometers, which measure wind speed.Most of our wind sensors are modified slightly from the manufacturers’ stock items so that they may be used with our data loggers in research, air quality, and general purpose meteorological applications.
•Accuracy:±1m/s
•Start Wind:0.2-0.4 m/s
▲Voltage output type
Range:0~32. 4 m/s
Supply voltage:7V~24 V DC
Output signals:0.4~2V or 0~5 V 、1~5 V
Wind speed values =(output voltage -0.4)/1.6*32.4
▲current output type
Range:0~32. 4 m/s
Supply voltagec:12V~24V DC
Output signals:4~20 mA
Load capacity:≤200Ω
Wind speed values =(output current -4)/16*32.4
▲Pulse Output type
Range:0~60 m/s
Output signals:pulse( 0.88m/s / pulse)
Supply voltage:5V~24V DC
▲ 485 type
Range:0~32. 4 m/s
Supply voltage:7V~24V DC
Communication protocol:Modbus-RTU